Fresh Concrete Filling Sensor
BI-100

    NEW
BI-100 measures the size of charged capacitance within the mold to determine the level of concrete in it. When concrete is poured in, BI-100 can detect exposed aggregate and inadequately filled spots from outside the mold. It can clearly show spots that require re-shaking and other actions to prevent defects.
   
   
-
Specifications BI-100
Detection method high-frequency capacitance checking method
Display method LED (three-stage indicator: red light on, green light flashing, green light on)
Power source two 1.5 V batteries (AA alkali)
Dimension & Weight 275 x dia50 mm, Net 0.4 kg
Accessories two1.5 V batteries (AA alkali), strap
Options soft case
Source FY 2006 conference of the Architectural Institute of Japan (Kanto)

© Copyright 2000 Kett Electric Laboratory, All rights reserved.